Diverter Valve Selection Guide

Conveying Valves

Plug, plunger and damper types, working pressure ≤ 0.2 to ≤ 4 bar.

Overview

Working pressure
≤ 0.2 / ≤ 2.5 / ≤ 4 bar
Size range
1-1/2" ~ 20" (by model)
Media temperature
-10 ~ 120 °C
Use
Combining or splitting material flows
Scope
Design, supply, installation and commissioning

Diverter valves combine or split material flows in pneumatic conveying lines. We offer plug, plunger and damper types; selection depends mainly on working pressure, material, size and branch angle. We provide design, supply, installation and commissioning.

Model comparison

ModelDesignMaterialWorking pressureSize rangeStandard branch angleMaterial of construction
PDVPlugPellets and powders≤ 4 bar1-1/2"–12"45° (other angles on request)Body CF8 or aluminium; product-contact parts CF8
GDVPlungerPellets≤ 2.5 bar4"–12"45°Body CF8 or aluminium; product-contact parts CF8
DP/SDamper, straight-throughPellets and powders≤ 0.2 bar4"–20"C45° / C60° / C90°SS304
DP/ADamper, bypassPellets and powders≤ 0.2 bar4"–20"L30° / L45° / L60°SS304

Media temperature -10 ~ 120 °C. PDV and GDV flanges PN10, ANSI 150#, others on request; CF8M on request. DP/S and DP/A flanges per customer requirement. Custom sizes, flanges and materials are available on request.

How to choose

01

Above 2.5 bar

Choose PDV: working pressure up to 4 bar, soft seat for zero leakage, for pellets and powders.

02

Pellets, up to 2.5 bar

Consider GDV: few parts, low drive torque, easy to maintain.

03

Up to 0.2 bar

Consider DP/S or DP/A, straight-through or bypass depending on the pipeline layout.

FAQ

Which actuation options are available?

PDV and GDV are available with manual or pneumatic actuation.

What do you need for a quotation?

Tell us the material, working pressure, size, branch angle and pipeline layout.

Planning a new line or an upgrade?

Tell us your material, capacity and distance – our engineers will reply with a conveying concept and quotation.